Operation point of a fluorite ore dressing plant

1. At present, the daily processing capacity is 200 per day, and the grinding treatment volume is strictly controlled between 8 tons and 9 tons per hour. The grinding overflow concentration is controlled between 30-35%, and the grinding fineness is controlled between -200 mesh and 80%-85%. The amount of processing and the degree of concentration must be strictly controlled: the ball miller measures the thickness of the shift 4 times per shift, registers it on the record book, and adjusts the grind concentration according to the measurement results and requirements.

Thickness measurement time per shift:

Day shift: 10:30 13:30 16:30 19:30

Night shift: 22:30 1:30 4:30 7:30

2. The preparation of the drug should be strictly in accordance with the preparation requirements, and the dosage of the drug-filled barrel should be prepared on time. The flow of the drug needs to be stable. During the normal production process, the flow of the pipe and the faucet should be checked to ensure that the faucet and the pipe are not blocked, and the agent can flow smoothly and quantitatively. .

Concentration and flow rate of the drug preparation: aluminum sulfate concentration 11% flow rate 25ml/L

Water glass concentration 6% flow rate 11ml/L

Silicone concentration 9% coarse selection 35ml / s sweep one, fine sweep 13 ml / s

Fine one, fine two, fine three 10ml/s fine four, fine five 8ml/s fine six, fine seven 5ml/s

Collector : Oleic acid: 5ml/s Saponified oleic acid: 40ml/s.

3. The agent of aluminum sulfate, water glass and silicone mixing tank needs to be stirred every hour for 5 minutes to prevent the precipitation of the drug and ensure the dissolution of the drug. The saponified oleic acid and oleic acid should be heated, and the slurry must be added after heating to hot. Pay attention to check the heating facilities to ensure the heating conditions. When adding oleic acid, you can't wait until the oleic acid in the tank is fast flowing. When the amount of oleic acid in the tank is half, add oleic acid immediately, otherwise the temperature in the tank can't be heated in time. Set the temperature.

4. During the flotation process, the slurry temperature control of the flotation tank must be in accordance with the temperature requirements, the rough selection temperature is controlled between 32-35 degrees, and the selected temperature is controlled between 25-28 degrees. The floatability of fluorite and calcium carbonate has a lot to do with temperature. Temperature control is important, not too high or too low, and needs to be controlled as required.

5. During the flotation process, the flotation operation requires no troughing, no troughing, and observing the foam phenomenon. The fluorite flotation foam is mainly composed of small dense and viscous foam, no large bubbles, no bubbles, and foam looks. Sticky, heavy, and foamed by hand. The color of the fluorite concentrate is dark yellow, similar to brown. If the foam is white, the amount of impurity calcium carbonate is large. When there is a bubble or vacuole in the foam, the first thing that comes to mind is that the amount of oleic acid and saponified oleic acid in the collector is not enough; the phenomenon of returning the pulp and not blistering indicates that the inhibitor is excessively gelatinous and needs to be appropriately reduced. The amount of glue used. The flotation process, the roughing, the surface scan mineral slurry to be controlled somewhat higher, so that most of the scraping up fluorite; six fine, fine seven, eight pulp refined to control some low level, additional water should be large.

6. Sample test and test 3 times per shift, take samples every hour, one sample every four hours, test and test.

White class: 9-12 13-16 17-21

Night shift: 21-24 1-4 5-9

Preparation method of saponified oleic acid:

The weight ratio of oleic acid to sodium carbonate is 3:1. The oleic acid is added to the upper small medicinal tank to be heated to a hot state, and sodium carbonate is weighed to one-third of the weight of the oleic acid, and added to the chemical tank to inject hot water to heat the sodium carbonate aqueous solution. The oleic acid switch is turned on during the stirring of the sodium carbonate solution, the flow rate is small, and the oleic acid is poured while stirring, and the mixture is thoroughly stirred.

Laser Components

Optical Components and Accessories, including a wide selection of Laser Diode , Laser Crystal, Optical Lenses, Optical Filters, Optical Mirrors, Windows, Prisms, Beam splitters, Beam combiner, Beam Expander, Temperature controlled Heatsink , etc.. They are integrated into a limitless number of applications, such as microscopy, imaging, or interferometry for industries ranging from the life sciences to testing and measurement.

Laser Diode
Laser Optics

405-1550 nm, output power up to 250 W.

Components725 Free space laser diodes

Components725 Fiber Coupled Laser diodes module


Laser Diode

Precision optical components.

Components725 Laser crystal

Components725 Frequency doubling crystal

Components725 Lens and Filter


laser optics
Fiber Coupler & Fiber & Fiber Optic Collimator
Line Generator

Optical Fiber from visible to near IR.

Components725 Fiber coupler

Components725 Multi-mode/ Single-mode fiber
Components725 Fiber optic collimator


fiber coupler
Powel lens is available with fan angles of 5°, 7°, 10°, 30°, 45°, 60°, 75° 90° and 100°
Line Generator
Fiber Beam Combiner Beam Combiner
Combines up to 4 fibers into 1 beam.
(single mode or multimode optional)

Fiber Beam Combiner

2 to 5 wavelengths combiner.

Components725 Multi-combiner
Components725 Polarization beam splitter/combiner

Beam Combiner
Multi-function Optical System Beam Expander
Complete solution of optical system with multi-function.
Multi-function Optical System
Expansion ratio of 2X, 3X, 5X, 10X beam expanders.
Beam Expander
AOM & Shutter
Heatsink
AOM (Acousto-optic modulator) with repetition rate up to 1MHz.
Shutter with minimum exposure as low as to 5ms.
shutter
It can provide a constant temperature for laser to make the laser more stable
Heatsink
LCD Electronic Timer Multi-pulse Generator Multi-pulse Generator
Used for cumulatively recording the working time (life time) of lasers. Cumulative time deviation ≤0.02%
LCD Electronic Timer Multi-pulse Generator
Generate pulse signal, high and low electronic level 0-10000/ms variable.
 Multi-pulse Generator
Articulated Arm

Variable Attenuator

Used in conjunction with various types of CO2, YAG, and other wavelengths Laser Systems as a means of delivering the laser energy from the laser launch to the process point.
Articulated Arm
Circular and square attenuators which can vary the output power from 0.1%-100%.
Attenuator

Laser Goggles

Laser Safety Protective Housing
Laser safety is the key important thing during laser operation. CNI can offer proper laser goggles that protect from laser damage.
Laser Goggles
Laser safety is the key important thing during laser operation. CNI can offer laser safety protective housing that protect from laser damage.
Laser Safety Protective Housing
Laser Viewing Card
Laser Rangefinder
Hand-held infrared viewers for observation and alignment, wavelengths available from 800 to 1550 nm.
ir viewer
Laser rangefinder has a long lifetime with low power consumption, easy to assemble and use.
Laser Rangefinder

Laser Components,Blue Laser Goggles,Cheap Laser Printer,Articulated Arm Series

Changchun New Industries Optoelectronics Technology Co., Ltd. , https://www.cnioptics.com